manufacturer of measuring instruments
English Česky Africa China Español Français Magyar Polski Sweden USA UAE

IoT Wireless Temperature Datalogger for 2 external probes, with two two-state inputs, built-in 2G modem

GSM Datalogger is designed to record from two external temperature probes and two two-state inputs. In case of exceeded set limits, SMS and JSON messages can be sent via GPRS data connection. Measured values can be sent to the internet storage COMET Cloud, which is a complete monitoring, alarm and analysis system.

It is also possible to set the regular sending of JSON messages to COMET Database, the sending interval is adjustable. Alarms are also indicated locally by LED, LCD and acoustically by built-in beeper.
The recording is performed in a non-volatile electronic memory. The data can be transferred to a PC via included USB-C cable.

GSM recorder includes Traceable calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard.

 

  • code
    U0843M
  • Warranty
    3 years

Technical data

Measured value

Temperature
Two-state signal

TEMPERATURE SENSOR - external probe Pt1000

Measuring range -200 to +260 °C
Accuracy ±0.2°C; ±0,2 % of the measurement value in a range of +100 to +260 °C
Resolution 0.1 °C
Response time t90 of temperature measurement (temperature step 20°C, air flow approximately 1m/s) according to the connected probe

BINARY INPUT

Parameters of the voltage contact „L“ level input voltage:< 0,4 V(*);
„H“ level input voltage:> 2 V;
Minimum voltage applicable:0 V;
Maximum voltage applicable:+30 V DC
Parameters of the voltage-free contact Contact resistance in „switched-on“ state:< 10 kOhm;
Contact resistance in the „switched-off“ state:> 300 kOhm;
Contact voltage in the „switched-off“ state:ca 3 V;
Minimum state duration necessary for latching the state:1s

GSM MODEM PARAMETERS

Quad-band 850/900/1800/1900MHz
Compliant to GSM Phase2/2+
GPRS GPRS mobile station class B
Class 4 2W @ 850/900MHz
Class 1 1W @ 1800/1900MHz

GENERAL TECHNICAL DATA

Operating temperature -20 to +60 °C
Channels 2x external temperature probe, 2x binary input
Memory 500,000 values in noncyclic logging mode; 350,000 values in cyclic record mode
Recording interval to the internal memory adjustable from 1 second to 24 hours
Recording interval to the COMET Cloud from 5 minutes
Interval for measuring and evaluating alarms adjustable 1 s, 10 s, 1 min
Recording mode noncyclic - data logging stops after filling the memory
cyclic - after filling memory oldest data is overwritten by new
Real time clock year, leap year, month, day, hour, minute, second
Power rechargeable Li-Ion battery A8200, 3.6V/5200mAh
Protection class IP20
Dimensions 61 x 93 x 53 mm, with antenna 120 x 93 x 53 mm
Weight (including batteries) approx. 270 g
Warranty 3 years

Optional accessories and download

Temperature probe Pt1000TG8/0, without connector

Temperature probe Pt1000TG8/0, without connector

Temperature range: -80 to 200°C
code SN104
Temperature probe Pt1000TG8/0, without connector, cable 2 meters

Temperature probe Pt1000TG8/0, without connector, cable 2 meters

Temperature range: -80 to 200°C
code SN105
Temperature probe Pt1000TG8/0, without connector, cable 5 meters

Temperature probe Pt1000TG8/0, without connector, cable 5 meters

Temperature range: -80 to 200°C
code SN108
Temperature probe Pt1000TG8/0, without connector, cable 10 meters

Temperature probe Pt1000TG8/0, without connector, cable 10 meters

Temperature range: -80 to 200°C
code SN113
Temperature probe 2061-250/0, without connector

Temperature probe 2061-250/0, without connector

Temperature range: -30 to 250°C
code SN147
Temperature probe 2061-250/0, without connector, cable 2 meters

Temperature probe 2061-250/0, without connector, cable 2 meters

Temperature range: -30 to 250°C
code SN148
Temperature probe 2061-250/0, without connector, cable 5 meters

Temperature probe 2061-250/0, without connector, cable 5 meters

Temperature range: -30 to 250°C
code SN151
Temperature probe 2061-250/0, without connector, cable 10 meters

Temperature probe 2061-250/0, without connector, cable 10 meters

Temperature range: -30 to 250°C
code SN156
Temperature probe Pt1000TG7/0, without connector

Temperature probe Pt1000TG7/0, without connector

Temperature range: -50 to 200°C
code SN164
Temperature probe Pt1000TG7/0, without connector, cable 2 meters

Temperature probe Pt1000TG7/0, without connector, cable 2 meters

Temperature range: -50 to 200°C
code SN165
Temperature probe Pt1000TG7/0, without connector, cable 5 meters

Temperature probe Pt1000TG7/0, without connector, cable 5 meters

Temperature range: -50 to 200°C
code SN166
Temperature probe Pt1000TG7/0, without connector, cable 10 meters

Temperature probe Pt1000TG7/0, without connector, cable 10 meters

Temperature range: -50 to 200°C
code SN167
Temperature probe 2304-220/0, without connector, cable 1 meter

Temperature probe 2304-220/0, without connector, cable 1 meter

Temperature range: -30 to 220°C
code SN168
Temperature probe 2021-150/0, without connector, cable 1 meter

Temperature probe 2021-150/0, without connector, cable 1 meter

Temperature range: -30 to 150°C
code SN169
Temperature probe PTS350A-2/0, without connector, cable 2 meters

Temperature probe PTS350A-2/0, without connector, cable 2 meters

Temperature range: -30 to 130°C
code SN170
Temperature probe 2034-220/0, without connector, cable 1 meter

Temperature probe 2034-220/0, without connector, cable 1 meter

Temperature range: -30 to 150°C
code SN175
Temperature probe 2061-200/0, without connector, cable 1 meter

Temperature probe 2061-200/0, without connector, cable 1 meter

Temperature range: -50 to 200°C
code SN178
Temperature probe 2061-200/0, without connector, cable 2 meters

Temperature probe 2061-200/0, without connector, cable 2 meters

Temperature range: -50 to 200°C
code SN179
Temperature probe 2061-200/0, without connector, cable 5 meters

Temperature probe 2061-200/0, without connector, cable 5 meters

Temperature range: -50 to 200°C
code SN180
Temperature probe 2061-200/0, without connector, cable 10 meters

Temperature probe 2061-200/0, without connector, cable 10 meters

Temperature range: -50 to 200°C
code SN181
Temperature probe PTS350A-5/0, without connector, cable 5 meters

Temperature probe PTS350A-5/0, without connector, cable 5 meters

Temperature range: -30 to 130°C
code SN182
Temperature probe PTS350A-10/0, without connector, cable 10 meters

Temperature probe PTS350A-10/0, without connector, cable 10 meters

Temperature range: -30 to 130°C
code SN183
Temperature probe Pt1000TGL40/0, without connector, cable 1 meter

Temperature probe Pt1000TGL40/0, without connector, cable 1 meter

Temperature range: -30 to 80°C
code SN185
Temperature probe Pt1000TGL40/0, without connector, cable 2 meters

Temperature probe Pt1000TGL40/0, without connector, cable 2 meters

Temperature range: -30 to 80°C
code SN186
Temperature probe Pt1000TGL40/0, without connector, cable 5 meters

Temperature probe Pt1000TGL40/0, without connector, cable 5 meters

Temperature range: -30 to 80°C
code SN187
Temperature probe Pt1000TGL40/0, without connector, cable 10 meters

Temperature probe Pt1000TGL40/0, without connector, cable 10 meters

Temperature range: -30 to 80°C
code SN188
Temperature probe Pt1000TR160/0, without connector, cable 1 meter

Temperature probe Pt1000TR160/0, without connector, cable 1 meter

Temperature range: -30 to 80°C
code SN199
Temperature probe Pt1000TR160/0, without connector, cable 2 meters

Temperature probe Pt1000TR160/0, without connector, cable 2 meters

Temperature range: -30 to 80°C
code SN200
Temperature probe Pt1000TR160/0, without connector, cable 5 meters

Temperature probe Pt1000TR160/0, without connector, cable 5 meters

Temperature range: -30 to 80°C
code SN201
Temperature probe Pt1000TR160/0, without connector, cable 10 meters

Temperature probe Pt1000TR160/0, without connector, cable 10 meters

Temperature range: -30 to 80°C
code SN202
Temperature probe Pt1000TR160/0, without connector, cable 15 meters

Temperature probe Pt1000TR160/0, without connector, cable 15 meters

Temperature range: -30 to 80°C
code SN203
Temperature probe Pt1000TR160/0, without connector, cable 20 meters

Temperature probe Pt1000TR160/0, without connector, cable 20 meters

Temperature range: -30 to 80°C
code SN204
PTS380K/0 temperature sensor with a stainless steel connection head and connector

PTS380K/0 temperature sensor with a stainless steel connection head and connector

Temperature range: -30 to 100°C
code SN205
Stick-in probe 2091-250/0, without connector, cable 1 meter

Stick-in probe 2091-250/0, without connector, cable 1 meter

Temperature range: -50 to 250°C
code SN210
Stick-in probe 2091-250/0, without connector, cable 2 meters

Stick-in probe 2091-250/0, without connector, cable 2 meters

Temperature range: -50 to 250°C
code SN211
Stick-in probe 2091-250/0, without connector, cable 5 meters

Stick-in probe 2091-250/0, without connector, cable 5 meters

Temperature range: -50 to 250°C
code SN212
Stick-in probe 2091-250/0, without connector, cable 10 meters

Stick-in probe 2091-250/0, without connector, cable 10 meters

Temperature range: -50 to 250°C
code SN213
Special probe 2071-80/0, without connector

Special probe 2071-80/0, without connector

Temperature range: -30 to 80°C
code SN214
Temperature probe Pt1000TG68/0, without connector, cable 2 meters

Temperature probe Pt1000TG68/0, without connector, cable 2 meters

Temperature range: -50 to 200°C
code SN232
Temperature probe Pt1000TG68/0, without connector, cable 5 meters

Temperature probe Pt1000TG68/0, without connector, cable 5 meters

Temperature range: -50 to 200°C
code SN233
Temperature probe Pt1000TG68/0, without connector, cable 10 meters

Temperature probe Pt1000TG68/0, without connector, cable 10 meters

Temperature range: -50 to 200°C
code SN234
Temperature probe Pt1000TR125/0, without connector, cable 1 meter

Temperature probe Pt1000TR125/0, without connector, cable 1 meter

Temperature range: -190 to 150°C
code SN239
Temperature probe Pt1000TR125/0, without connector, cable 2 meters

Temperature probe Pt1000TR125/0, without connector, cable 2 meters

Temperature range: -190 to 150°C
code SN240
Temperature probe Pt1000TR125/0, without connector, cable 5 meters

Temperature probe Pt1000TR125/0, without connector, cable 5 meters

Temperature range: -190 to 150°C
code SN241
Cryogenic temperature probe Pt1000TR125/0, without connector, cable 10 meters

Cryogenic temperature probe Pt1000TR125/0, without connector, cable 10 meters

Temperature range: -190 to 150°C
code SN242
Temperature probe Pt1000TR050S/0, without connector, cable 1 meter

Temperature probe Pt1000TR050S/0, without connector, cable 1 meter

Temperature range: -50 to 400°C
Discontinued
Temperature probe Pt1000TR050S/0, without connector, cable 2 meters

Temperature probe Pt1000TR050S/0, without connector, cable 2 meters

Temperature range: -50 to 400°C
Discontinued
Temperature probe Pt1000TR050S/0, without connector, cable 5 meters

Temperature probe Pt1000TR050S/0, without connector, cable 5 meters

Temperature range: -50 to 400°C
Discontinued
Ultra thin temperature probe Pt1000TG3/0, without connector

Ultra thin temperature probe Pt1000TG3/0, without connector

Temperature range: -50 to 200°C
code SN252
Ultra thin temperature probe Pt1000TG3/0, without connector, cable 2 meters

Ultra thin temperature probe Pt1000TG3/0, without connector, cable 2 meters

Temperature range: -50 to 200°C
code SN254
Ultra thin temperature probe Pt1000TG3/0, without connector, cable 5 meters

Ultra thin temperature probe Pt1000TG3/0, without connector, cable 5 meters

Temperature range: -50 to 200°C
code SN255
Ultra thin temperature probe Pt1000TG3/0, without connector, cable 10 meters

Ultra thin temperature probe Pt1000TG3/0, without connector, cable 10 meters

Temperature range: -50 to 200°C
code SN256
Temperature probe Pt1000TR050S/0, without connector, cable 10 meters

Temperature probe Pt1000TR050S/0, without connector, cable 10 meters

Temperature range: -50 to 400°C
Discontinued
Ambient temperature probe, 201-80/C

Ambient temperature probe, 201-80/C

Temperature range: -30 to 80°C
code SN258
Temperature probe Pt1000TG8Ex/0, without connector, for ATEX zone II

Temperature probe Pt1000TG8Ex/0, without connector, for ATEX zone II

Temperature range: -30 to 180°C
code SN263
Temperature probe Pt1000TG8Ex/0, without connector, for ATEX zone II, cable 2 meters

Temperature probe Pt1000TG8Ex/0, without connector, for ATEX zone II, cable 2 meters

Temperature range: -30 to 180°C
code SN264
Temperature probe Pt1000TG8Ex/0, without connector, for ATEX zone II, cable 5 meters

Temperature probe Pt1000TG8Ex/0, without connector, for ATEX zone II, cable 5 meters

Temperature range: -30 to 180°C
code SN265
Temperature probe Pt1000TG8Ex/0, without connector, for ATEX zone II, cable 10 meters

Temperature probe Pt1000TG8Ex/0, without connector, for ATEX zone II, cable 10 meters

Temperature range: -30 to 180°C
code SN266
Temperature probe Pt1000TG8Ex/0, without connector, for ATEX zone II, cable 15 meters

Temperature probe Pt1000TG8Ex/0, without connector, for ATEX zone II, cable 15 meters

Temperature range: -30 to 180°C
code SN267
Temperature probe Pt1000TR050M/0, without connector, cable 1 meter

Temperature probe Pt1000TR050M/0, without connector, cable 1 meter

Temperature range: -50 to 400°C
code SN270
Temperature probe Pt1000TR050M/0, without connector, cable 2 meters

Temperature probe Pt1000TR050M/0, without connector, cable 2 meters

Temperature range: -50 to 400°C
code SN271
Temperature probe Pt1000TR050M/0, without connector, cable 5 meters

Temperature probe Pt1000TR050M/0, without connector, cable 5 meters

Temperature range: -50 to 400°C
code SN272
Temperature probe Pt1000TR050M/0, without connector, cable 10 meters

Temperature probe Pt1000TR050M/0, without connector, cable 10 meters

Temperature range: -50 to 400°C
code SN273

AC/DC adapter 230Vac to 5Vdc/2.1 A, EU

AC/DC adapter 230Vac to 5Vdc/2.1 A, EU

code A1879eu
AC/DC adapter 230Vac to 5Vdc/2.1 A, UK

AC/DC adapter 230Vac to 5Vdc/2.1 A, UK

code A1879uk
AC/DC adapter 230Vac to 5Vdc/2.1 A, US

AC/DC adapter 230Vac to 5Vdc/2.1 A, US

code A1879us
Accupack A8205 for dataloggers "U"

Accupack A8205 for dataloggers "U"

code A8205

Accredited temperature calibration

Accredited temperature calibration

code SLU001

USB-C cable, 1 meter

USB-C cable, 1 meter

code MP053

Wall holder for datalogger

Wall holder for datalogger

code LP100
Holder for mounting the GSM or CO2 Datalogger on magnetic surfaces

Holder for mounting the GSM or CO2 Datalogger on magnetic surfaces

code LP103

COMET Database

COMET Database

code CDB
COMET Cloud

COMET Cloud

code cloud
COMET Cloud Lite for Android & iOS

COMET Cloud Lite for Android & iOS

code cloud_app
COMET VISION - Analytical Software for Dataloggers and Multiloggers

COMET VISION - Analytical Software for Dataloggers and Multiloggers

code CV
Database Viewer for Comet Database

Database Viewer for Comet Database

code DBV

Magnetic door contact SA-200-A

Magnetic door contact SA-200-A

code SA200A
Magnetic door contact with cable length 10m

Magnetic door contact with cable length 10m

code SA200A-10
Magnetic door contact with cable length 15m

Magnetic door contact with cable length 15m

code SA200A-15
Magnetic door contact with cable length 2m

Magnetic door contact with cable length 2m

code SA200A-2
Magnetic door contact with cable length 20m

Magnetic door contact with cable length 20m

code SA200A-20
Magnetic door contact with cable length 30m

Magnetic door contact with cable length 30m

code SA200A-30
Magnetic door contact with cable length 5m

Magnetic door contact with cable length 5m

code SA200A-5
Power detector SP008

Power detector SP008

code SP008

IoT ready Flat Rate SIM Card

IoT ready Flat Rate SIM Card

code LP105

COMET presentation case for samples

COMET presentation case for samples

code BM512
COMET Magnetic Foldable Stand

COMET Magnetic Foldable Stand

code PPO001

Software

download-icon Comet Vision Software (2.3.8935.24346 dbapi 21.1)
16.56 MB
download-icon Comet Database One Click Installer (21.1-V)
487.31 MB
download-icon Conversions - application for recalculation of values
694.50 KB
download-icon COMET Cloud Lite - Android (Google Play)
download-icon COMET Cloud Lite - iOS (App Store)

Others

download-icon Terms and Conditions COMET System s.r.o.
133.12 KB

Manuals

download-icon Instruction Manual
3.90 MB
download-icon Quick Start Manual
1.08 MB
download-icon Safety Information
335.90 KB
download-icon Manual for Calibration (accuracy verification) and Adjustment for Dataloggers Uxxxx(M)
427.80 KB
download-icon Declaration of Conformity
96.91 KB

Catalogs

download-icon CATALOG - Dataloggers
3.57 MB
download-icon CATALOG - GSM loggers
3.00 MB
download-icon Catalogue Sheets - COMET GSM Data Loggers
2.33 MB

Related products

COMET Cloud

COMET Cloud

code cloud
COMET Database

COMET Database

code CDB
IoT Wireless Temperature Datalogger with built-in sensor and 2G modem

IoT Wireless Temperature Datalogger with built-in sensor and 2G modem

code U0110M
IoT Wireless Temperature Datalogger for 4 external probes, with built-in 2G modem

IoT Wireless Temperature Datalogger for 4 external probes, with built-in 2G modem

code U0141M
IoT Wireless Temperature and Relative Humidity Datalogger, with built-in 2G modem

IoT Wireless Temperature and Relative Humidity Datalogger, with built-in 2G modem

code U3120M
IoT Wireless Temperature and Relative Humidity Datalogger for external probe, with built-in 2G modem

IoT Wireless Temperature and Relative Humidity Datalogger for external probe, with built-in 2G modem

code U3121M
IoT Wireless Temperature and Relative Humidity Datalogger with connector for other temperature probe, with built-in 2G modem

IoT Wireless Temperature and Relative Humidity Datalogger with connector for other temperature probe, with built-in 2G modem

code U3631M
IoT Wireless Temperature, Relative Humidity, CO2 and atmospheric pressure Datalogger with built-in 2G modem

IoT Wireless Temperature, Relative Humidity, CO2 and atmospheric pressure Datalogger with built-in 2G modem

code U4440M
IoT Wireless Datalogger for 3 current inputs 0-20mA and 1 two-state input, with built-in 2G modem

IoT Wireless Datalogger for 3 current inputs 0-20mA and 1 two-state input, with built-in 2G modem

code U6841M
IoT Wireless Four channel Datalogger with pulse and two-state inputs, with built-in 2G modem

IoT Wireless Four channel Datalogger with pulse and two-state inputs, with built-in 2G modem

code U7844M
IoT Wireless CO2 datalogger with built-in sensor, 2G modem

IoT Wireless CO2 datalogger with built-in sensor, 2G modem

code U8410M
Wireless thermometer, hygrometer barometer, Sigfox IoT

Wireless thermometer, hygrometer barometer, Sigfox IoT

code W7810