RH+T+Tdp cable probe, 2 meters cable length, output 4-20mA

Humidity, temperature transmitter. Outdoor, indoor use.

Relative humidity, temperature sensors at probe on the cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.

The device is supplied with T+RH probe with 2 meters cable.

 

  • code
    T3111-2
  • Warranty
    3 years

Technical data

Measured value

Temperature
Relative humidity
Counted values (dew point…)

TEMPERATURE SENSOR

Measuring range -30 to +105 °C
Accuracy ±0.4 °C
Resolution 0.1 °C

HUMIDITY SENSOR

Measuring range 0 to 100 % RH
Accuracy ±2.5 % RH from 5 to 95 % at 23 °C
Resolution 0.1% RH

DEW POINT

Measuring range -60 to +80 °C
Accuracy ±1.5 °C at ambient temperature T <25 °C and RH >30 %
Resolution 0.1 °C

GENERAL TECHNICAL DATA

Operating temperature -30 to +80 °C
Channels 1x connectable temperature+humidity probe
Counted values dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
Output 4-20 mA, galvanic isolated
Range of humidity sensor temperature compensation all temperature range
Configuration of output user adjustable from PC; measured range + value
Power 9-30 Vdc
Protection class IP65 electronics; IP40 sensors
Dimensions 88,5 x 145 x 39,5 mm; length/diameter of external probe 88/18 mm
External probe cable length 2 meters
Weight approx. 210 g
Warranty 3 years

Optional accessories and download

Accredited temperature and relative humidity calibration

Accredited temperature and relative humidity calibration

code SLU003

cable for transmitter adjustment via USB port

cable for transmitter adjustment via USB port

code SP003

Wall holder for external probes DIGIL

Wall holder for external probes DIGIL

code SP009

sintered bronze sensor protection

sintered bronze sensor protection

code F0000
plastic sensor protection with stainless filter (black)

plastic sensor protection with stainless filter (black)

code F5200B
PTFE sensor protection, white

PTFE sensor protection, white

code F5300

COMETEO Professional Thermometer Screen for Weather Station Sensor

COMETEO Professional Thermometer Screen for Weather Station Sensor

code F8000

Humidity Standard 10%RH, set 5pcs

Humidity Standard 10%RH, set 5pcs

code HM023
Humidity Standard 80%RH, set 5pcs

Humidity Standard 80%RH, set 5pcs

code HM024
Female connector ELKA 4012PG7 for TxxxxL

Female connector ELKA 4012PG7 for TxxxxL

code K1427
Vessel for adjustment and calibration of humidity

Vessel for adjustment and calibration of humidity

code MD046
PP4 Flat circular flange

PP4 Flat circular flange

code PP4
PP90 Right-angled stainless steel flange

PP90 Right-angled stainless steel flange

code PP90
plastic gland for direct mounting of the humidity probe

plastic gland for direct mounting of the humidity probe

code SP004
Tool for easy connection to WAGO terminals 236 for analog output transmitters

Tool for easy connection to WAGO terminals 236 for analog output transmitters

code SP005
Transmitter version with watertight male connector

Transmitter version with watertight male connector

code TxxxxL

COMET presentation case for samples

COMET presentation case for samples

code BM512
COMET Magnetic Foldable Stand

COMET Magnetic Foldable Stand

code PPO001

Software

download-icon Conversions - application for recalculation of values
694.50 KB

Others

download-icon 3D model T3111
1.33 MB
download-icon Terms and Conditions COMET System s.r.o.
133.12 KB

Manuals

download-icon Instruction Manual
1.18 MB
download-icon Quick Start Manual
803.98 KB
download-icon Declaration of Conformity
103.18 KB

Catalogs

download-icon CATALOG - Analog Sensors with 0-10 V or 4-20 mA output
1.86 MB
download-icon Catalogue Sheets - COMET Transmitters
1.17 MB

Related products

Compressed air RH+T+Tdp sensor with 4-20mA output

Compressed air RH+T+Tdp sensor with 4-20mA output

code T3111P
Temperature and humidity outdoor, indoor probe with 4-20mA output

Temperature and humidity outdoor, indoor probe with 4-20mA output

code T3110
Temperature and humidity duct probe with 4-20mA output

Temperature and humidity duct probe with 4-20mA output

code T3113
COMETEO Professional Thermometer Screen for Weather Station Sensor

COMETEO Professional Thermometer Screen for Weather Station Sensor

code F8000