manufacturer of measuring instruments
English Česky Africa China Español Français Magyar Polski Sweden USA UAE

Dual channel logger with pulse and binary input

Data logger is designed for record of pulses and two-state events. Values are stored to a non volatile electronic memory. Data transfer to the personal computer for further analysis is performed via USB, RS232, GSM or Ethernet interface by means of a proper communication adapter.

The device includes Traceable calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard.

For communication with the PC must be from Optional accessories ordered USB adapter or COM adapter or start/stop magnet if is needed to control logging the other way than directly from computer.

 

  • code
    S7021
  • Warranty
    3 years

Technical data

COUNTER INPUT

Counter range in 16 bits mode 0 to 61 695 values
in 32 bits mode 0 to 2 021 654 527 values
Signal for binary input from potential - less contact or two - state voltage signal
Minimum pulse duration at counter input: 1 ms (shorter pulses may not be recorded)
Maximum frequency on binary input 500 Hz
Current through closed contact 30 µA
Voltage across open contact max 3.6 V
LOW voltage level on binary input 0 to +0,2 V (proud ze vstupu max. 30 µA)
HIGH voltage level on binary input +3 to +30 V, current to input max. 100 nA
Connector for connection of input signals CYESN 9 pins

BINARY INPUT

Minimum pulse duration on binary input 500 ms (shorter pulses will not be recorded)
Maximum frequency on binary input 0,5 Hz (i.e maximum of 5 pulses for 10 s)
Power current of connected contact 3 µA (contact closed)
Voltage across open contact max 3.6 V
LOW voltage level on binary input 0 to +0.2 V, current from input max. 3 µA
HIGH voltage level on binary input +3 to +30 V, current to input max. 100 nA
Connector for connection of input signals CYESN 9 pins

GENERAL TECHNICAL DATA

Operating temperature -30 to +70 °C
Channels 1x counter, 1x binary input
Memory 32,000 values
Recording interval adjustable from 10 s to 24 h
Display and alarm refresh each 10 s
Recording mode noncyclic - data logging stops after filling the memory
cyclic - after filling memory oldest data is overwritten by new
Real time clock year, leap year, month, day, hour, minute, second
Power lithium battery 3.6 V; size AA
Battery life 5 years
Protection class IP67
Dimensions (without connectors) 93 x 64 x 29 mm
Weight (including batteries) approx. 115 g
Warranty 3 years

Optional accessories and download